Sic.Framework-Nanjing-Baishi/MECF.Framework.RT.Equipment.../PmDevices/IoSHArH2Switch.cs

150 lines
5.0 KiB
C#
Raw Normal View History

2023-04-13 11:51:03 +08:00
using Aitex.Core.RT.Device;
using Aitex.Core.RT.Device.Devices;
using Aitex.Core.RT.Device.Unit;
using Aitex.Core.RT.Log;
using Aitex.Core.RT.OperationCenter;
using Aitex.Core.Util;
using System;
using System.Collections.Generic;
using System.Diagnostics;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using System.Xml;
using static Aitex.Core.RT.Device.PmDevices.DicMode;
namespace Aitex.Core.RT.Device.PmDevices
{
public class IoSHArH2Switch : BaseDevice, IDevice
{
private IValve _valve1;
private IValve _valve2;
private IValve _valve3;
private IValve _valve4;
//private IValve _valve5;
//private IValve _valve6;
private int _openValveInfo = 1;
private DeviceTimer _timer = new DeviceTimer();
public IoSHArH2Switch(string module, XmlElement node, string ioModule = "")
{
var attrModule = node.GetAttribute("module");
base.Module = string.IsNullOrEmpty(attrModule) ? module : attrModule;
base.Name = node.GetAttribute("id");
base.Display = node.GetAttribute("display");
base.DeviceID = node.GetAttribute("schematicId");
_valve1 = DEVICE.GetDevice($"{Module}.{node.GetAttribute("valve1")}") as IValve;
_valve2 = DEVICE.GetDevice($"{Module}.{node.GetAttribute("valve2")}") as IValve;
_valve3 = DEVICE.GetDevice($"{Module}.{node.GetAttribute("valve3")}") as IValve;
_valve4 = DEVICE.GetDevice($"{Module}.{node.GetAttribute("valve4")}") as IValve;
//_valve5 = DEVICE.GetDevice($"{Module}.{node.GetAttribute("valve5")}") as IValve;
//_valve6 = DEVICE.GetDevice($"{Module}.{node.GetAttribute("valve6")}") as IValve;
Debug.Assert(_valve1 != null, $"Valve setting not valid");
Debug.Assert(_valve2 != null, $"Valve setting not valid");
Debug.Assert(_valve3 != null, $"Valve setting not valid");
Debug.Assert(_valve4 != null, $"Valve setting not valid");
//Debug.Assert(_valve5 != null, $"Valve setting not valid");
//Debug.Assert(_valve6 != null, $"Valve setting not valid");
}
public bool Initialize()
{
OP.Subscribe($"{Module}.{Name}.SetValve", SetValve);
return true;
}
private bool SetValve(out string reason, int time, object[] param)
{
return SetValve(out reason, param[0].ToString());
}
public bool SetValve(out string reason, string arH2Switch)
{
reason = string.Empty;
ArH2Switch gas = (ArH2Switch)Enum.Parse(typeof(ArH2Switch), arH2Switch, true);
switch (gas)
{
case ArH2Switch.Ar:
if (!_valve1.TurnValve(false, out reason))
return false;
if (!_valve2.TurnValve(true, out reason))
return false;
if (!_valve3.TurnValve(true, out reason))
return false;
if (!_valve4.TurnValve(true, out reason))
return false;
//if (!_valve5.TurnValve(false, out reason))
// return false;
//if (!_valve6.TurnValve(true, out reason)) //放到定时器延迟处理防止InterLock
// return false;
_openValveInfo = 2;
break;
case ArH2Switch.H2:
if (!_valve1.TurnValve(true, out reason))
return false;
if (!_valve2.TurnValve(false, out reason))
return false;
if (!_valve3.TurnValve(true, out reason))
return false;
if (!_valve4.TurnValve(true, out reason))
return false;
//if (!_valve5.TurnValve(true, out reason))//放到定时器延迟处理防止InterLock
// return false;
//if (!_valve6.TurnValve(false, out reason))
// return false;
_openValveInfo = 1;
break;
default:
break;
}
//_timer.Start(600);
return true;
}
public void Terminate()
{
}
public void Monitor()
{
try
{
//if (_timer.IsTimeout())
//{
// _timer.Stop();
// if (_openValveInfo == 1)
// {
// _valve5.TurnValve(true, out string reason);
// }
// else if (_openValveInfo == 2)
// {
// _valve6.TurnValve(true, out string reason);
// }
//}
}
catch (Exception ex)
{
LOG.Write(ex);
}
}
public void Reset()
{
}
}
}