namespace MECF.Framework.RT.EquipmentLibrary.HardwareUnits.UPS
{
public class EATONUPS:UPSBase
{
public EATONUPS(string module, string name, string scRoot) : base(module, name, scRoot)
{
Oids.Add("InputVoltage", ".1.3.6.1.4.1.534.1.3.4.1.2.1");//输入电压输入电压为0说明使用UPS xupsInputVoltage
Oids.Add("BatteryVoltage", ".1.3.6.1.4.1.534.1.2.2.0");//电池当前电压V xupsBatVoltage
Oids.Add("BatteryRemainsTime", ".1.3.6.1.4.1.534.1.2.1.0");//剩余时间s,要除60 xupsBatTimeRemaining
Oids.Add("upsOutputSource", ".1.3.6.1.4.1.534.1.4.5.0");//当前输出源 xupsOutputSource
Oids.Add("BatteryUnderResidue", ".1.3.6.1.4.1.534.1.2.4.0");//电量剩余百分比,直接用数值 xupsBatCapacity
}
public override void ParseOutputSource(string value)
{
// xupsOutputSource DESCRIPTION
// SYNTAX INTEGER {
// other(1),
//none(2),
//normal(3),
//bypass(4),
//battery(5),
//booster(6),
//reducer(7),
//parallelCapacity(8),
//parallelRedundant(9),
//highEfficiencyMode(10),
//maintenanceBypass(11),
//essMode(12)
//}
//"The present source of output power. The enumeration
// none(2) indicates that there is no source of output
// power(and therefore no output power), for example,
// the system has opened the output breaker.
// 'normal', 'bypass', and 'battery' indicate those common UPS statuses.
// 'booster' and 'reducer' indicate boost or buck operation, for
// line - interactive UPSs only.
// 'parallelCapacity' and 'parallelRedundant' indicate a normal parallel
// UPS system, in either Parallel for Capacity or Redundancy configuration.
// 'highEfficiencyMode' is normal but enhanced by High Efficiency mode.
// 'maintenanceBypass' indicates that the UPS is in Maintenance / Manual
// Bypass mode.
// 'essMode' is normal but enhanced by Energy Saver System.
// 'other' covers any other, unusual conditions."
if (value == "2") //None
{
UPSPowerAlarm = true;
}
else
UPSPowerAlarm = false;
}
public override void ParseBatteryRemainsTime(string value)
{
BatteryRemainsTime = Convert.ToInt32(value)/60;
}
public override void ParseBatteryVoltage(string value)
{
BatteryVoltage = Convert.ToSingle(value);
}
public override void ParseInputVoltage(string value)
{
InputVoltage = Convert.ToSingle(value);
}
}
}