93 lines
3.0 KiB
C#
93 lines
3.0 KiB
C#
using Aitex.Core.Common.DeviceData.IoDevice;
|
|
using Aitex.Core.RT.DataCenter;
|
|
using Aitex.Core.RT.Event;
|
|
using Aitex.Core.RT.IOCore;
|
|
using Aitex.Core.RT.SCCore;
|
|
using Aitex.Core.Util;
|
|
using MECF.Framework.Common.Aitex.Core.Common.DeviceData.IoDevice;
|
|
using System.Xml;
|
|
|
|
namespace Aitex.Core.RT.Device.Devices
|
|
{
|
|
public class IoLineHeater : BaseDevice, IDevice
|
|
{
|
|
//配置中标记的AI名称
|
|
|
|
protected readonly AIAccessor _aiTemp;
|
|
|
|
protected readonly DOAccessor _doLineHeaterEnable;
|
|
|
|
protected readonly string _scNameAlarmHigh;
|
|
|
|
protected double _alarmHigh;
|
|
|
|
protected readonly R_TRIG _trigIsAlarm = new R_TRIG();
|
|
|
|
protected int _alarmCount;
|
|
|
|
|
|
private readonly LineHeaterData _lineHeaterData = new();
|
|
public LineHeaterData lineHeaterData
|
|
{
|
|
get
|
|
{
|
|
_lineHeaterData.LineHeaterLaber = Display;
|
|
_lineHeaterData.ScHighTemp = _alarmHigh;
|
|
_lineHeaterData.TempValue = _aiTemp.Value;
|
|
|
|
return _lineHeaterData;
|
|
}
|
|
}
|
|
|
|
public IoLineHeater(string module, XmlElement node, string ioModule = "") : base(module, node, ioModule)
|
|
{
|
|
_aiTemp = ParseAiNode("aiHeatTMA", node, ioModule);
|
|
|
|
_doLineHeaterEnable = ParseDoNode("doLineHeaterEnable", node, ioModule);
|
|
|
|
_scNameAlarmHigh = $"{ScBasePath}.{node.GetAttribute("scAlarmHigh")}";
|
|
}
|
|
|
|
protected override void HandleMonitor()
|
|
{
|
|
if (_alarmHigh == 0)
|
|
return;
|
|
if (_aiTemp.Value >= _alarmHigh)
|
|
{
|
|
_trigIsAlarm.CLK = true;
|
|
if (_trigIsAlarm.Q)
|
|
{
|
|
if (_doLineHeaterEnable == null)
|
|
{
|
|
EV.PostWarningLog(Module,
|
|
$"{_aiTemp.Name} {_aiTemp.Value} over temperature {_alarmHigh} but doLineHeaterEnable can not be off since it's not defined");
|
|
}
|
|
else
|
|
{
|
|
_doLineHeaterEnable.SetValue(false, out _);
|
|
EV.PostWarningLog(Module,
|
|
$"{_aiTemp.Name} {_aiTemp.Value} over temperature {_alarmHigh}\r\n{Module}.{_doLineHeaterEnable.Name} force off");
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
public bool Initialize()
|
|
{
|
|
DATA.Subscribe($"{Module}.LineHeater.{Display}", () => _aiTemp.Value);
|
|
DATA.Subscribe($"{Module}.{Name}.LineHeaterData", () => lineHeaterData, SubscriptionAttribute.FLAG.IgnoreSaveDB);
|
|
_alarmHigh = SC.SafeGetValue(_scNameAlarmHigh, double.PositiveInfinity);
|
|
SC.RegisterValueChangedCallback(_scNameAlarmHigh, v => _alarmHigh = (double)v);
|
|
return true;
|
|
}
|
|
|
|
public void Reset()
|
|
{
|
|
_trigIsAlarm.RST = true;
|
|
}
|
|
|
|
public void Terminate()
|
|
{
|
|
}
|
|
}
|
|
} |