using System;
|
|
using System.Text;
|
|
using Aitex.Core.RT.Device;
|
|
using Aitex.Core.RT.Device.Unit;
|
|
using Aitex.Core.RT.Event;
|
|
using Aitex.Core.RT.Routine;
|
|
using Aitex.Core.RT.SCCore;
|
|
using MECF.Framework.Common.Equipment;
|
|
using MECF.Framework.RT.EquipmentLibrary.HardwareUnits.LoadLocks;
|
|
using Mainframe.Devices;
|
|
using Mainframe.TMs;
|
|
using System.Diagnostics;
|
|
|
|
namespace Mainframe.LLs
|
|
{
|
|
public class LoadLockPumpRoutine : LoadLockBaseRoutine
|
|
{
|
|
enum RoutineStep
|
|
{
|
|
CheckForelinePressure,
|
|
RequestPump,
|
|
RequestPumpDelay,
|
|
SlowPump,
|
|
CloseSlowValve,
|
|
FastPump,
|
|
PumpDelay,
|
|
CloseFastValve,
|
|
Delay,
|
|
TimeDelay1,
|
|
}
|
|
|
|
private double _pumpBasePressure=0;
|
|
private double _forelineBasePressure;
|
|
private double _pumpSwitchPressure;
|
|
|
|
private int _waitForelineTimeout;
|
|
private int _slowPumpTimeout;
|
|
private int _fastPumpTimeout;
|
|
private int _pumpDelayTime = 5;
|
|
private int _routineTimeOut;
|
|
|
|
private IoInterLock _tmIoInterLock;
|
|
|
|
private bool _useSettingValue;
|
|
|
|
private Stopwatch _swTimer = new Stopwatch();
|
|
|
|
public LoadLockPumpRoutine(ModuleName module )
|
|
{
|
|
Module = module.ToString();
|
|
Name = "Pump";
|
|
|
|
_tmIoInterLock = DEVICE.GetDevice<IoInterLock>("TM.IoInterLock");
|
|
}
|
|
|
|
public void Init()
|
|
{
|
|
_useSettingValue = false;
|
|
}
|
|
|
|
public void Init(double basePressure, int pumpDelayTime)
|
|
{
|
|
_pumpBasePressure = basePressure;
|
|
_pumpDelayTime = pumpDelayTime;
|
|
_useSettingValue = true;
|
|
}
|
|
|
|
public override Result Start(params object[] objs)
|
|
{
|
|
Reset();
|
|
|
|
string reason;
|
|
|
|
|
|
if (!LoadLockDevice.SetFastVentValve(false, out reason) || !LoadLockDevice.SetSlowVentValve(false, out reason))
|
|
{
|
|
EV.PostAlarmLog(Module, $"Can not turn off valves, {reason}");
|
|
return Result.FAIL;
|
|
}
|
|
|
|
bool isAtmMode = SC.GetValue<bool>("System.IsATMMode");
|
|
|
|
_forelineBasePressure = SC.GetValue<double>("LoadLock.ForelinePressureBase");
|
|
_pumpSwitchPressure = SC.GetValue<double>("LoadLock.Pump.SlowFastPumpSwitchPressure");
|
|
_waitForelineTimeout = SC.GetValue<int>("LoadLock.WaitForelinePressureTimeout");
|
|
_slowPumpTimeout = SC.GetValue<int>("LoadLock.Pump.SlowPumpTimeout");
|
|
_fastPumpTimeout = SC.GetValue<int>("LoadLock.Pump.FastPumpTimeout");
|
|
_routineTimeOut = SC.GetValue<int>("LoadLock.Pump.RoutineTimeOut");
|
|
|
|
if (!_useSettingValue)
|
|
{
|
|
_pumpBasePressure = SC.GetValue<double>("LoadLock.Pump.PumpBasePressure");
|
|
_pumpDelayTime = SC.GetValue<int>("LoadLock.Pump.PumpDelayTime");
|
|
}
|
|
|
|
if (!TMDevice.SetFastPumpValve(false, out reason))
|
|
{
|
|
EV.PostAlarmLog(Module, $"can not pump, TM fast pump value can not close");
|
|
return Result.FAIL;
|
|
}
|
|
|
|
if (isAtmMode)
|
|
{
|
|
EV.PostInfoLog(Module, $"system in atm mode, {LoadLockDevice.Module} pump skipped");
|
|
return Result.DONE;
|
|
}
|
|
if (SC.ContainsItem("LoadLock.RunPumpRoutineEventBelowBasePressure") && !SC.GetValue<bool>("LoadLock.RunPumpRoutineEventBelowBasePressure"))
|
|
{
|
|
if (LoadLockDevice.ChamberPressure < _pumpBasePressure)
|
|
{
|
|
EV.PostInfoLog(Module, $"{LoadLockDevice.Module} already under pump base pressure");
|
|
return Result.DONE;
|
|
}
|
|
}
|
|
|
|
if (!LoadLockDevice.CheckLidClose())
|
|
{
|
|
EV.PostAlarmLog(Module, $"Can not pump, lid is open");
|
|
return Result.FAIL;
|
|
}
|
|
|
|
if (!TMDevice.CheckSlitValveClose(ModuleHelper.Converter(LoadLockDevice.Module)))
|
|
{
|
|
EV.PostAlarmLog(Module, $"Can not pump, slit valve is open");
|
|
return Result.FAIL;
|
|
}
|
|
if (!TMDevice.SetTmToLLVent(false, out _))
|
|
{
|
|
EV.PostAlarmLog(Module, $"can not pump,can not close v85!");
|
|
}
|
|
|
|
if (!_tmIoInterLock.SetLLPumpRoutineRunning(true, out reason))
|
|
{
|
|
EV.PostAlarmLog(Module, $"can not pump,{reason}");
|
|
return Result.FAIL;
|
|
}
|
|
|
|
//LockPump2(out reason);
|
|
|
|
_swTimer.Restart();
|
|
Notify("Start");
|
|
return Result.RUN;
|
|
}
|
|
|
|
|
|
public override Result Monitor()
|
|
{
|
|
try
|
|
{
|
|
CheckRoutineTimeOut();
|
|
|
|
TimeDelay((int)RoutineStep.RequestPumpDelay, 1);
|
|
|
|
SlowPump((int)RoutineStep.SlowPump, _pumpSwitchPressure, _slowPumpTimeout);
|
|
|
|
FastPump((int)RoutineStep.FastPump, _pumpBasePressure, _fastPumpTimeout);
|
|
|
|
TimeDelay((int)RoutineStep.PumpDelay, _pumpDelayTime);
|
|
|
|
CloseFastPumpValve((int)RoutineStep.CloseFastValve);
|
|
|
|
CloseSlowPumpValve((int)RoutineStep.CloseSlowValve);
|
|
}
|
|
catch (RoutineBreakException)
|
|
{
|
|
return Result.RUN;
|
|
}
|
|
catch (RoutineFaildException)
|
|
{
|
|
LoadLockDevice.SetSlowPumpValve(false, out _);
|
|
LoadLockDevice.SetFastPumpValve(false, out _);
|
|
//UnlockPump2();
|
|
return Result.FAIL;
|
|
}
|
|
|
|
Notify($"Finished ! Elapsed time: {(int)(_swTimer.ElapsedMilliseconds / 1000)} s");
|
|
_tmIoInterLock.DoLLPumpDownRoutineRunning = false;
|
|
|
|
//UnlockPump2();
|
|
|
|
return Result.DONE;
|
|
}
|
|
|
|
public override void Abort()
|
|
{
|
|
_tmIoInterLock.DoLLPumpDownRoutineRunning = false;
|
|
base.Abort();
|
|
}
|
|
|
|
private void CheckRoutineTimeOut()
|
|
{
|
|
if (_routineTimeOut > 10)
|
|
{
|
|
if ((int)(_swTimer.ElapsedMilliseconds / 1000) > _routineTimeOut)
|
|
{
|
|
EV.PostAlarmLog(Module, $"Routine TimeOut! over {_routineTimeOut} s");
|
|
throw (new RoutineFaildException());
|
|
}
|
|
}
|
|
}
|
|
|
|
}
|
|
}
|