using Aitex.Core.RT.Device;
using Aitex.Core.RT.Device.Unit;
using Aitex.Core.RT.Event;
using Aitex.Core.RT.Routine;
using Aitex.Core.RT.SCCore;
using MECF.Framework.Common.DBCore;
using MECF.Framework.Common.Equipment;
using SicPM.Devices;
using System;
using System.Collections.Generic;
using System.Diagnostics;
namespace SicPM.Routines
{
public class PMLeakCheckRoutine : PMBaseRoutine
{
private enum RoutineStep
{
RotationEnable,
HeatEnable,
VentPumpClose,
ArSupply,
SetGroupA,
SetGroupB,
SetGroupC,
SetGroupE,
SetGroupF,
SetGroupH,
SetGroupD,
SetGroupG,
SetGroupK,
SetMFCMode,
SetPCMode,
SetM1to16,
SetPC,
SetGroupJ,
SetM291519to38,
SetGasOut,
SetTv,
SetGasIn1, //V68
OpenFinal1, //V91-96
SetMfcFinal1, //M32-38
SetMfc19to26,
SetTVCloseMode,
SetTvPositionToZero,
SetGasIn2,
SetGroupJOpen,
SetM291519to26,
OpenFinal2,
2022-08-08 14:36:38 +08:00
CloseFinal2,
2022-07-26 09:41:07 +08:00
SetMfcFinal2,
SetEPV1,
SetEPV2,
SetTvMode,
2022-08-08 14:36:38 +08:00
SetTVEnable,
SetTVPressMode,
SetTv1,
WaitTv1,
SetM2toM40,
SetTVPositionMode,
2022-08-17 11:03:59 +08:00
SetTVPositionMode_1,
2022-08-08 14:36:38 +08:00
SetTVPositionMax,
2022-08-17 11:03:59 +08:00
SetTVPositionMax_1,
2022-08-08 14:36:38 +08:00
SetTVPressMode1,
SetM2TOM40Default,
SetM2toM40_1,
2022-07-26 09:41:07 +08:00
SetTvOpen,
SetTvModeToPress,
SetTVtoCurrent,
RoutinePre,
SetPressureUp,
SetPressureDown,
WaitPressureDown,
WaitPressureUp,
VentPumpOpen,
PressureToMax,
PressureToMin,
StartLoop,
EndLoop,
SetMfc28to31,
SetReactorPress,
CloseFinanl1,
CloseFinanl2,
CloseEPV2,
SetTVCloseMode2,
CLoseTvvvv,
SetEPVVV2,
CLoseEPV1,
CheckPM1000,
WaitPressUpTo1000,
WaitPressUpTo1020,
SetPressUpOrDown1,
SetPressUpOrDown2,
SetMfc28to40Special,
WaitPmPressureUp,
SetMfc28to40Default,
SetV75,
SetV76,
SetV751,
SetV761,
SetPC567Close,
SetPC567Mode,
SetPC567Default,
OpenEPV2,
WaitPressUpTo20,
SetMfc291519to38,
WaitPressUpTo0,
SetMfc291519to38ToDefault,
WaitPressDownTo20,
SetPmPressureTo20,
CloseMfcFinal1,
CloseMfcFinal2,
CloseMfc2915,
CheckFinal1Open,
DoLeakCheck,
CalcLeakCheck,
SetTVClose,
CloseTV,
CloseV27,
CloseV28,
CloseV69,
CloseV70,
SetGroupV25,
2022-08-08 14:36:38 +08:00
SetV31,
SetV32,
SetV35V36,
2022-07-26 09:41:07 +08:00
2022-07-30 08:50:44 +08:00
SetV92V93V95,
SetV94,
SetV96,
SetV68,
SetM32M35M37,
SetM36,
SetM38,
CloseM32M35M37,
CloseM36,
CloseM38,
CloseGasIn1,
2022-07-26 09:41:07 +08:00
TimeDelay1,
TimeDelay2,
TimeDelay3,
TimeDelay4,
TimeDelay5,
TimeDelay6,
TimeDelay7,
TimeDelay8,
TimeDelay9,
TimeDelay10,
TimeDelay11,
TimeDelay12,
TimeDelay13,
2022-07-30 08:50:44 +08:00
TimeDelay14,
2022-08-22 09:48:03 +08:00
TimeDelay15,
TimeDelay16,
2022-09-01 08:43:27 +08:00
TimeDelay17,
2022-07-26 09:41:07 +08:00
}
enum LeakCheckType
{
ChamberOnly,
ChamberAndGasline,
ChamberAndGaslineToFacility,
}
private ModuleName moduleName;
private IoThrottleValve2 _IoThrottle;
private IoInterLock _pmIoInterLock;
List<int> _lstPcList = new List<int> { 1, 2, 3, 4, 5, 6, 7 };
private int _rotationCheckSpeed = 0; //设置旋转速度为0后检查是否转速低于此数值
private int _rotationCloseTimeout; //旋转停止超时
private int _heatTimeOut = 5; //Heat关闭等待Di反馈超时时间
private double _pressureMax; //Loop压力上限可设置600-800
private double _pressureMin; //Loop压力下限可设置 0-400
private int _pressureLoopCount; //Loop次数
private int _pressureMinDelay;
private int _pressureMaxDelay;
private int _pressureMinTimeout;
private int _pressureMaxTimeout;
private int _IoValueOpenCloseTimeout = 10; //开关阀门超时时间
private double _pmPressureMaxDiff; //蝶阀与目标压力的差值范围(认为调整到位了)
private int _throttleTimeout; //蝶阀调整到指定压力的超时时间
private int _paramContinuePumpTime;
private int _paramLeakCheckTime ;
private double _beginPressure;
private double _beginTime;
private int _calTimes; //第几次计算LeakCheck的值每60秒计算一次
private double _leakSpec;
private int _routineTimeOut;
2022-07-30 08:50:44 +08:00
//private int _EPV2OpenDelayTime = 9;
2022-07-26 09:41:07 +08:00
private bool _useSettingValue = false;
private Stopwatch _swTimer = new Stopwatch();
public int ElapsedTime
{
get { return _swTimer.IsRunning ? (int)(_swTimer.ElapsedMilliseconds / 1000) : 0; }
}
public PMLeakCheckRoutine(ModuleName module, PMModule pm) : base(module, pm)
{
Module = module.ToString();
Name = "Leak Check";
_IoThrottle = DEVICE.GetDevice<IoThrottleValve2>($"{Module}.TV");
}
internal void Init(int pumpTime, int leakCheckTime)
{
_paramContinuePumpTime = pumpTime;
_paramLeakCheckTime = leakCheckTime;
_useSettingValue = true;
}
internal void Init()
{
_useSettingValue = false;
}
public override Result Start(params object[] objs)
{
Reset();
_swTimer.Restart();
_rotationCloseTimeout = SC.GetValue<int>($"PM.{Module}.RotationCloseTimeout");
_pmPressureMaxDiff = SC.GetValue<double>($"PM.{Module}.ThrottlePressureMaxDiff");
_throttleTimeout = SC.GetValue<int>($"PM.{Module}.ThrottlePressureTimeout");
_pmIoInterLock = DEVICE.GetDevice<IoInterLock>($"{Module}.PMInterLock");
_rotationCloseTimeout = SC.GetValue<int>($"PM.{Module}.RotationCloseTimeout");
_pressureLoopCount = SC.GetValue<int>($"PM.{Module}.LeakCheck.CyclePurgeCount");
_pressureMin = SC.GetValue<double>($"PM.{Module}.LeakCheck.PumpBasePressure");
_pressureMinDelay = SC.GetValue<int>($"PM.{Module}.LeakCheck.PumpDelayTime");
_pressureMinTimeout = SC.GetValue<int>($"PM.{Module}.LeakCheck.PumpTimeout");
_pressureMax = SC.GetValue<double>($"PM.{Module}.LeakCheck.VentBasePressure");
_pressureMaxDelay = SC.GetValue<int>($"PM.{Module}.LeakCheck.VentDelayTime");
_pressureMaxTimeout = SC.GetValue<int>($"PM.{Module}.LeakCheck.VentTimeout");
_routineTimeOut = SC.GetValue<int>($"PM.{Module}.LeakCheck.RoutineTimeOut");
2022-07-30 08:50:44 +08:00
//_EPV2OpenDelayTime = SC.GetValue<int>($"PM.{Module}.TimeDelayAlterEPV2Open");
2022-07-26 09:41:07 +08:00
if (!_useSettingValue)
{
_paramContinuePumpTime = SC.GetValue<int>($"PM.{Module}.LeakCheck.ContinuePumpTime");
_paramLeakCheckTime = SC.GetValue<int>($"PM.{Module}.LeakCheck.LeakCheckDelayTime");
}
_leakSpec = SC.GetValue<double>($"PM.{Module}.LeakCheck.LeakSpec");
if (!PMDevice.SetIOValueByGroup(IoGroupName.V70, false))
{
EV.PostAlarmLog(Module,"Can not close V70-1");
return Result.FAIL;
}
Notify($"Start LoopCount:{_pressureLoopCount}");
return Result.RUN;
}
public override Result Monitor()
{
try
{
CheckRoutineTimeOut();
2022-08-08 14:36:38 +08:00
//关闭V76,打开V75
SetIoValueByGroup((int)RoutineStep.SetV76, IoGroupName.V76, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetV75, IoGroupName.V75, true, _IoValueOpenCloseTimeout);
//旋转停止,加热停止
2022-07-26 09:41:07 +08:00
SetHeatEnable((int)RoutineStep.HeatEnable, false, _heatTimeOut);
2022-08-08 14:36:38 +08:00
SetRotationValve((int)RoutineStep.RotationEnable, _rotationCheckSpeed, false, _rotationCloseTimeout);
2022-07-26 09:41:07 +08:00
2022-08-08 14:36:38 +08:00
//关闭V72,打开V25
2022-07-26 09:41:07 +08:00
SetIoValueByGroup((int)RoutineStep.VentPumpClose, IoGroupName.VentPump, false, _IoValueOpenCloseTimeout);
2022-08-08 14:36:38 +08:00
SetIoValueByGroup((int)RoutineStep.SetGroupV25, IoGroupName.V25, true, _IoValueOpenCloseTimeout);
2022-07-26 09:41:07 +08:00
2022-08-08 14:36:38 +08:00
//打开V31,打开V32
SetIoValueByGroup((int)RoutineStep.SetV31, IoGroupName.V31, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetV32, IoGroupName.V32, true, _IoValueOpenCloseTimeout);
//打开V35,打开V36
SetIoValueByGroup((int)RoutineStep.SetV35V36, IoGroupName.V35V36, true, _IoValueOpenCloseTimeout);
//关闭B/C/E/F/H/K 阀门
2022-07-26 09:41:07 +08:00
SetIoValueByGroup((int)RoutineStep.SetGroupB, IoGroupName.B, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupC, IoGroupName.C, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupE, IoGroupName.E, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupF, IoGroupName.F, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupH, IoGroupName.H, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupK, IoGroupName.K, false, _IoValueOpenCloseTimeout);
2022-08-08 14:36:38 +08:00
//打开D/G 阀门
2022-07-26 09:41:07 +08:00
SetIoValueByGroup((int)RoutineStep.SetGroupD, IoGroupName.D, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupG, IoGroupName.G, true, _IoValueOpenCloseTimeout);
2022-08-08 14:36:38 +08:00
//设置MFC和PC的模式
2022-07-26 09:41:07 +08:00
SetMfcModeToNormalByGroup((int)RoutineStep.SetMFCMode, MfcGroupName.All);
SetPcModeToNormal((int)RoutineStep.SetPCMode, _lstPcList);
2022-08-08 14:36:38 +08:00
//M1-M16设定为default值(M2、M9、M15除外)
2022-07-26 09:41:07 +08:00
SetMfcToDefaultByGroup((int)RoutineStep.SetM1to16, MfcGroupName.M1to16, 0);
2022-08-08 14:36:38 +08:00
//设置所有PC到默认值
2022-07-26 09:41:07 +08:00
SetPcToDefault((int)RoutineStep.SetPC, _lstPcList);
2022-08-08 14:36:38 +08:00
//设置M2,M9,M15,M19-M26 3s ramp 到default 值
SetMfcToDefaultByGroup((int)RoutineStep.SetM291519to26, MfcGroupName.M2toM26, 3);
//打开V68
2022-07-30 08:50:44 +08:00
SetIoValueByGroup((int)RoutineStep.SetV68, IoGroupName.GasIn1, true, _IoValueOpenCloseTimeout);
2022-08-08 14:36:38 +08:00
//打开J阀门
SetIoValueByGroup((int)RoutineStep.SetGroupJ, IoGroupName.J, true, _IoValueOpenCloseTimeout);
2022-07-26 09:41:07 +08:00
2022-08-08 14:36:38 +08:00
//打开EPV2
SetIoValueByGroup((int)RoutineStep.SetEPV2, IoGroupName.EPV2, true, _IoValueOpenCloseTimeout);
TimeDelay((int)RoutineStep.TimeDelay1, 3);
//设置蝶阀Enable
SetThrottleEnableAndWait((int)RoutineStep.SetTVEnable, _IoThrottle, 5);
//设置蝶阀为压力模式
SetThrottleToPressModeAndWait((int)RoutineStep.SetTVPressMode, _IoThrottle, 5);
2022-07-26 09:41:07 +08:00
2022-08-08 14:36:38 +08:00
//伺服压力设定值到0mbar
SetThrottlePressureAndWaitSetPoint((int)RoutineStep.SetTv1, _IoThrottle, _pressureMin, _pmPressureMaxDiff, _throttleTimeout);
2022-07-26 09:41:07 +08:00
2022-08-08 14:36:38 +08:00
//M2、M9、M15、M19-M40 MFC 3s ramp到0
SetMfcByGroup((int)RoutineStep.SetM2toM40, MfcGroupName.M2toM40, 0, 3);
2022-07-26 09:41:07 +08:00
2022-08-08 14:36:38 +08:00
//等待腔体压力Pump到设定值
WaitChamberPressDownTo((int)RoutineStep.WaitTv1, _pressureMin, _pmPressureMaxDiff, _throttleTimeout);
2022-08-22 09:48:03 +08:00
TimeDelay((int)RoutineStep.TimeDelay8, 3);
2022-08-08 14:36:38 +08:00
//蝶阀设置为位置模式,开度设置为最大
SetThrottleToPositionMode((int)RoutineStep.SetTVPositionMode, _IoThrottle, _throttleTimeout);
SetThrottleSetPosition((int)RoutineStep.SetTVPositionMax, _IoThrottle, 100, _throttleTimeout);
2022-08-22 09:48:03 +08:00
TimeDelay((int)RoutineStep.TimeDelay9,3);
2022-08-08 14:36:38 +08:00
//循环开始
2022-07-26 09:41:07 +08:00
Loop((int)RoutineStep.StartLoop, _pressureLoopCount);
2022-08-02 08:34:41 +08:00
2022-08-08 14:36:38 +08:00
//M2、M9、M15、M19-M40 MFC 3s ramp 到 default 值
SetMfcToDefaultByGroup((int)RoutineStep.SetM2TOM40Default, MfcGroupName.M2toM40, 3);
2022-08-17 11:03:59 +08:00
//设置蝶阀为压力模式
SetThrottleToPressModeAndWait((int)RoutineStep.SetTVPressMode1, _IoThrottle, 5);
2022-08-08 14:36:38 +08:00
//使用动态流量伺服到300mbar
SetPressureUpOrDown((int)RoutineStep.SetPressUpOrDown1, PressureUpOrDown.Uping);
SetThrottleToTargetAndNoWait((int)RoutineStep.SetPressureUp, _IoThrottle, _pressureMax);
WaitThrottleToPressureAndSetMfcSpecial((int)RoutineStep.WaitPressureUp, _IoThrottle, _pressureMax, _pmPressureMaxDiff, _pressureMaxTimeout);
2022-08-22 09:48:03 +08:00
TimeDelay((int)RoutineStep.TimeDelay10, _pressureMaxDelay);
2022-08-02 08:34:41 +08:00
2022-08-08 14:36:38 +08:00
//M2、M9、M15、M19-M40 MFC 3s ramp 0
SetMfcByGroup((int)RoutineStep.SetM2toM40_1, MfcGroupName.M2toM40, 0, 3);
//伺服到0mbar
2022-08-02 08:34:41 +08:00
SetThrottlePressureAndWait((int)RoutineStep.SetPressureDown, _IoThrottle, _pressureMin, _pmPressureMaxDiff, _throttleTimeout);
2022-08-17 11:03:59 +08:00
2022-08-22 09:48:03 +08:00
TimeDelay((int)RoutineStep.TimeDelay11,3);
2022-08-17 11:03:59 +08:00
//蝶阀设置为位置模式,开度设置为最大
SetThrottleToPositionMode((int)RoutineStep.SetTVPositionMode_1, _IoThrottle, _throttleTimeout);
SetThrottleSetPositionNoWait((int)RoutineStep.SetTVPositionMax_1, _IoThrottle, 100, _throttleTimeout);
2022-08-22 09:48:03 +08:00
TimeDelay((int)RoutineStep.TimeDelay12, _pressureMinDelay);
2022-08-02 08:34:41 +08:00
2022-07-26 09:41:07 +08:00
EndLoop((int)RoutineStep.EndLoop);
2022-08-08 14:36:38 +08:00
//依次关闭Final1
2022-07-30 08:50:44 +08:00
SetIoValueByGroup((int)RoutineStep.CloseGasIn1, IoGroupName.GasIn1, false, _IoValueOpenCloseTimeout);
2022-08-22 09:48:03 +08:00
Delay((int)RoutineStep.TimeDelay13, 5);
2022-07-30 08:50:44 +08:00
2022-08-08 14:36:38 +08:00
//关闭M32,M35,M36,M37,M38
2022-07-30 08:50:44 +08:00
SetMfcByGroup((int)RoutineStep.CloseM32M35M37, MfcGroupName.M32M35M37, 0, 5);
SetMfcByGroup((int)RoutineStep.CloseM36, MfcGroupName.M36, 0, 5);
SetMfcByGroup((int)RoutineStep.CloseM38, MfcGroupName.M38, 0, 5);
2022-08-22 09:48:03 +08:00
Delay((int)RoutineStep.TimeDelay14, 5);
2022-07-30 08:50:44 +08:00
2022-08-08 14:36:38 +08:00
//关闭Final1阀
2022-07-26 09:41:07 +08:00
SetIoValueByGroup((int)RoutineStep.CloseFinanl1, IoGroupName.Final1, false, _IoValueOpenCloseTimeout);
2022-08-08 14:36:38 +08:00
//关闭Final2
SetIoValueByGroup((int)RoutineStep.CloseFinal2, IoGroupName.Final2, false, _IoValueOpenCloseTimeout);
2022-07-26 09:41:07 +08:00
2022-08-08 14:36:38 +08:00
//延时
2022-08-22 09:48:03 +08:00
TimeDelay((int)RoutineStep.TimeDelay15, _paramContinuePumpTime);
2022-07-26 09:41:07 +08:00
2022-08-08 14:36:38 +08:00
//先关蝶阀,再关闭EPV2
SetThrottleToCloseMode((int)RoutineStep.SetTVCloseMode2, _IoThrottle, 8);
SetThrottleDisable((int)RoutineStep.CLoseTvvvv, _IoThrottle, 8);
2022-08-22 09:48:03 +08:00
TimeDelay((int)RoutineStep.TimeDelay16, 1);
2022-08-08 14:36:38 +08:00
SetIoValueByGroup((int)RoutineStep.SetEPVVV2, IoGroupName.EPV2, false, _IoValueOpenCloseTimeout);
2022-07-26 09:41:07 +08:00
2022-08-08 14:36:38 +08:00
//计算漏率
2022-07-26 09:41:07 +08:00
DoLeakCheck((int)RoutineStep.DoLeakCheck, _paramLeakCheckTime);
2022-09-01 08:43:27 +08:00
TimeDelay((int)RoutineStep.TimeDelay17, _paramLeakCheckTime);
CalcLeakCheck((int)RoutineStep.CalcLeakCheck, _paramLeakCheckTime);
//CalcLeackCheckPerMinute(_paramLeakCheckTime);
2022-07-26 09:41:07 +08:00
}
catch (RoutineBreakException)
{
return Result.RUN;
}
catch (RoutineFaildException)
{
return Result.FAIL;
}
_swTimer.Stop();
return Result.DONE;
}
public override void Abort()
{
Stop($"{Module} leak check aborted");
_swTimer.Stop();
PMDevice._ioThrottleValve.StopRamp();
PMDevice.SetMfcStopRamp(PMDevice.GetMfcListByGroupName(MfcGroupName.All));
PMDevice.SetRotationServo(0, 0);
base.Abort();
}
private void CheckRoutineTimeOut()
{
if (_routineTimeOut > 10)
{
if ((int)(_swTimer.ElapsedMilliseconds / 1000) > _routineTimeOut)
{
EV.PostAlarmLog(Module, $"Routine TimeOut! over {_routineTimeOut} s");
throw (new RoutineFaildException());
}
}
}
public void DoLeakCheck(int id, double time)
{
Tuple<bool, Result> ret = Execute(id, () =>
{
Notify($"Keep pressure for {time} seconds");
_beginTime = _swTimer.ElapsedMilliseconds;
_beginPressure = PMDevice.ChamberPressure;
_calTimes = 1;
return true;
});
if (ret.Item1)
{
if (ret.Item2 == Result.FAIL)
{
throw (new RoutineFaildException());
}
else
throw (new RoutineBreakException());
}
}
public void CalcLeackCheckPerMinute(int time)
{
//大于LeakCheck时间,
if ((int)((_swTimer.ElapsedMilliseconds - _beginTime) / 1000) >= time)
{
int leakSecond = (int)((_swTimer.ElapsedMilliseconds - _beginTime) / 1000);
double endPressure = PMDevice.ChamberPressure;
double leakSpan = endPressure - _beginPressure;
double leakRate = (endPressure - _beginPressure) / (leakSecond / 60.0);
if (leakRate > _leakSpec)
{
LeakCheckDataRecorder.Add(time, (int)_beginPressure, (int)endPressure, leakRate, Result.FAIL.ToString(), "", Module);
EV.PostInfoLog(Module, $"Leak check result: end at {DateTime.Now.ToString("HH:mm:ss")}, start: {_beginPressure:F2}mbar, end: {endPressure:F2}mbar, using {time} seconds, leak rate: {leakRate:F2}");
}
else
{
LeakCheckDataRecorder.Add(time, (int)_beginPressure, (int)endPressure, leakRate, Result.Succeed.ToString(), "", Module);
EV.PostInfoLog(Module, $"Leak check result: end at {DateTime.Now.ToString("HH:mm:ss")}, start: {_beginPressure:F2}mbar, end: {endPressure:F2}mbar, using {time} seconds, leak rate: {leakRate:F2}");
}
}
else
{
if ((int)((_swTimer.ElapsedMilliseconds - _beginTime) / 1000) >= 60 * _calTimes)
{
_calTimes++;
int leakSecond = (int)((_swTimer.ElapsedMilliseconds - _beginTime) / 1000);
double endPressure = PMDevice.ChamberPressure;
double leakSpan = endPressure - _beginPressure;
double leakRate = (endPressure - _beginPressure) / (leakSecond / 60.0);
if (leakRate > _leakSpec)
{
EV.PostInfoLog(Module, $"Leak check Failed Count {_calTimes - 1}: using {leakSecond} seconds, leak rate: {leakRate:F2} ,Rate over {_leakSpec}");
throw (new RoutineFaildException());
}
EV.PostInfoLog(Module, $"Leak check Count {_calTimes - 1}: using {leakSecond} seconds, leak rate: {leakRate:F2}");
}
throw (new RoutineBreakException());
}
}
public void CalcLeakCheck(int id, int time)
{
Tuple<bool, Result> ret = Execute(id, () =>
{
double endPressure = PMDevice.ChamberPressure;
double leakSpan = endPressure - _beginPressure;
double leakRate = (endPressure - _beginPressure) / (time / 60.0);
if (leakRate > _leakSpec)
{
LeakCheckDataRecorder.Add(time, (int)_beginPressure, (int)endPressure, leakRate, Result.FAIL.ToString(), "", Module);
EV.PostInfoLog(Module,$"Leak check result: end at {DateTime.Now.ToString("HH:mm:ss")}, start: {_beginPressure:F2}mbar, end: {endPressure:F2}mbar, using {time} seconds, leak rate: {leakRate:F2}");
return false;
}
else
{
LeakCheckDataRecorder.Add(time, (int)_beginPressure, (int)endPressure, leakRate, Result.Succeed.ToString(), "", Module);
EV.PostInfoLog(Module,$"Leak check result: end at {DateTime.Now.ToString("HH:mm:ss")}, start: {_beginPressure:F2}mbar, end: {endPressure:F2}mbar, using {time} seconds, leak rate: {leakRate:F2}");
return true;
}
});
}
}
}