using System.Diagnostics;
using Aitex.Core.RT.Device;
using Aitex.Core.RT.Device.Unit;
using Aitex.Core.RT.Event;
using Aitex.Core.RT.Routine;
using Aitex.Core.RT.SCCore;
using Mainframe.Devices;
using Mainframe.LLs;
using MECF.Framework.Common.Equipment;
using MECF.Framework.RT.EquipmentLibrary.HardwareUnits.LoadLocks;
using MECF.Framework.RT.EquipmentLibrary.HardwareUnits.TMs;
namespace Mainframe.TMs.Routines
{
public class TMPurgeRoutine : TMBaseRoutine
{
enum RoutineStep
{
StartLoop,
LoopPump,
LoopVent,
StopLoop,
//Pump
CloseV77,
CloseV80,
SlowPump,
FastPump,
VaccumDelay,
CloseValves,
CLoseSlowValue,
//Vent
CloseV81,
CloseV82,
SetMFC1,
SetMFC2,
OpenSlowVent,
OpenFastVent,
TimeStayATM,
CloseSlowVent,
ToBalancePressure
}
//private TMPumpRoutine _pumpRoutine;
//private TMVentRoutine _ventRoutine;
private TM _tm;
private IoSensor _bufferLid;
private IoSensor _tmLid;
private Devices.IoPump _pumpType;
private LoadLock _ll;
private IoInterLock _tmIoInterLock;
private Stopwatch _swTimer = new Stopwatch();
private int _routineTimeOut;
private int _purgeCount;
private double _slowFastPumpSwitchPressure;
private double _pumpDelayTime;
private double _pumpBasePressure;
private int _pumpTimeOut;
private double _ventBasePressure;
private double _slowFastVentSwitchPressure;
private int _slowVentTimeout;
private int _fastVentTime;
private double _mfc60Default1;
private double _mfc60Default2;
private SicPM.Devices.IoMFC _mfc60;
private double _ventDelayTime;
private bool _useSettingValue = false;
private TMPressureBalanceRoutine _balanceRoutine;
public TMPurgeRoutine()
{
Module = ModuleName.TM.ToString();
Name = "Purge";
_tm = DEVICE.GetDevice<SicTM>($"{ ModuleName.System.ToString()}.{ Module}");
_ll = DEVICE.GetDevice<SicLoadLock>($"LoadLock.LoadLock");
_bufferLid = DEVICE.GetDevice<IoSensor>($"Buffer.BufferLidClosed");
_tmLid = DEVICE.GetDevice<IoSensor>($"TM.TMLidClosed");
_pumpType = DEVICE.GetDevice<Devices.IoPump>($"TM.TMPump1");
_tmIoInterLock = DEVICE.GetDevice<IoInterLock>("TM.IoInterLock");
_mfc60 = DEVICE.GetDevice<SicPM.Devices.IoMFC>($"TM.Mfc60");
//_pumpRoutine = new TMPumpRoutine();
//_ventRoutine = new TMVentRoutine();
}
public void Init(int purgeCount, int pumpDelayTime)
{
_purgeCount = purgeCount;
_pumpDelayTime = pumpDelayTime;
}
public override Result Start(params object[] objs)
{
Reset();
if(!_useSettingValue)
{
_purgeCount = SC.GetValue<int>("TM.Purge.CyclePurgeCount");
_pumpBasePressure = SC.GetValue<double>("TM.Purge.PumpBasePressure");
_pumpDelayTime = SC.GetValue<int>("TM.Purge.PumpDelayTime");
_ventBasePressure = SC.GetValue<double>("TM.Purge.VentBasePressure");
_ventDelayTime = SC.GetValue<int>("TM.Purge.PumpDelayTime");
}
_balanceRoutine = new TMPressureBalanceRoutine();
_balanceRoutine.Init(ModuleName.PM1);
_routineTimeOut = SC.GetValue<int>("TM.Purge.RoutineTimeOut");
_slowFastPumpSwitchPressure = SC.GetValue<double>("TM.Purge.SlowFastPumpSwitchPressure");
_pumpTimeOut = SC.GetValue<int>("TM.Purge.PumpTimeOut");
_mfc60Default1 = SC.GetValue<double>("TM.Purge.Mfc60Default1");
_mfc60Default2 = SC.GetValue<double>("TM.Purge.Mfc60Default2");
_slowFastVentSwitchPressure = SC.GetValue<double>("TM.Purge.SlowFastVentSwitchPressure");
_slowVentTimeout = SC.GetValue<int>("TM.Purge.SlowVentTimeout");
_fastVentTime = SC.GetValue<int>("TM.Purge.FastVentTimeout");
ModuleName[] modules = new ModuleName[] { ModuleName.LoadLock, ModuleName.PM1 };
foreach (var moduleName in modules)
{
if (!_tm.CheckSlitValveClose(moduleName))
{
EV.PostAlarmLog(Module, $"Can not Purge, {moduleName} slit valve not closed");
return Result.FAIL;
}
}
if (!_bufferLid.Value)
{
EV.PostAlarmLog(Module, $"Can not Purge,Buffer lid is not open");
return Result.FAIL;
}
if (!_tmLid.Value)
{
EV.PostAlarmLog(Module, $"Can not Purge,TM lid is not open");
return Result.FAIL;
}
if (_pumpType.IsAlarm)
{
EV.PostAlarmLog(Module, $"can not Purge,TM pump alarm");
return Result.FAIL;
}
if (!_pumpType.IsRunning)
{
EV.PostAlarmLog(Module, $"can not Purge,TM pump is not running");
return Result.FAIL;
}
if (!_tmIoInterLock.SetTMPurgeRoutineRunning(true, out string reason))
{
EV.PostAlarmLog(Module, $"can not Purge,{reason}");
return Result.FAIL;
}
if (SC.GetValue<bool>("System.IsATMMode"))
{
return Result.DONE;
}
_swTimer.Restart();
Notify("Start");
return Result.RUN;
}
public override Result Monitor()
{
try
{
CheckRoutineTimeOut();
Loop((int)RoutineStep.StartLoop, _purgeCount);
//ExecuteRoutine((int)RoutineStep.LoopPump, _pumpRoutine);
//ExecuteRoutine((int)RoutineStep.LoopVent, _ventRoutine);
//先Pump
{
//关闭V77
CloseTMVent((int)RoutineStep.CloseV77);
//关闭V80
//CloseBufferVent((int)RoutineStep.CloseV80);
//打开V82,等待压力低于200mbar(可配置)
OpenSlowPump((int)RoutineStep.SlowPump, _tm, _slowFastPumpSwitchPressure, _pumpTimeOut);
//打开V81,压力达到0mbar(可配置)
OpenFastPump((int)RoutineStep.FastPump, _tm, _pumpBasePressure, _pumpTimeOut);
//等待5s(可配置)
TimeDelay((int)RoutineStep.VaccumDelay, _pumpDelayTime);
//关闭
CloseFastPump((int)RoutineStep.CloseValves, _tm);
CloseSlowPump((int)RoutineStep.CLoseSlowValue, _tm);
}
//再Vent
{
//关闭V80
//CloseBufferVent((int)RoutineStep.CloseV80);
//关闭V81
CloseFastPump((int)RoutineStep.CloseV81);
//关闭V82
CloseSlowPump((int)RoutineStep.CloseV82);
//设定MFC60慢充流量
SetMFCToSetPoint((int)RoutineStep.SetMFC1, _mfc60, _mfc60Default1);
//打开V77,等待压力大于200mbar
OpenSlowVent((int)RoutineStep.OpenSlowVent, _tm, _slowFastVentSwitchPressure, _slowVentTimeout);
//设定MFC60快充流量
SetMFCToSetPoint((int)RoutineStep.SetMFC2, _mfc60, _mfc60Default2);
//等待压力大于1020mbar
OpenFastVent((int)RoutineStep.OpenFastVent, _tm, _ventBasePressure, _fastVentTime);
//等待5s
TimeDelay((int)RoutineStep.TimeStayATM, _ventDelayTime);
//关闭V77
CloseSlowVentValve((int)RoutineStep.CloseSlowVent, _tm);
}
EndLoop((int)RoutineStep.StopLoop);
//关闭V81
CloseFastPump((int)RoutineStep.CloseV81);
//关闭V82
CloseSlowPump((int)RoutineStep.CloseV82);
//关闭V77
CloseSlowVentValve((int)RoutineStep.CloseSlowVent, _tm);
// 预抽气到PM平衡压力防止PM由于等待压力导致降温过度
ExecuteRoutine((int)RoutineStep.ToBalancePressure, _balanceRoutine);
}
catch (RoutineBreakException)
{
return Result.RUN;
}
catch (RoutineFaildException)
{
return Result.FAIL;
}
Notify($"Finished ! Elapsed time: {(int)(_swTimer.ElapsedMilliseconds / 1000)} s");
_tmIoInterLock.DoTmCyclePurgeRoutineRunning = false;
return Result.DONE;
}
public override void Abort()
{
_tmIoInterLock.DoTmCyclePurgeRoutineRunning = false;
//_pumpRoutine.Abort();
//_ventRoutine.Abort();
base.Abort();
}
private void CheckRoutineTimeOut()
{
if (_routineTimeOut > 10)
{
if ((int)(_swTimer.ElapsedMilliseconds / 1000) > _routineTimeOut)
{
EV.PostAlarmLog(Module, $"Routine TimeOut! over {_routineTimeOut} s");
throw (new RoutineFaildException());
}
}
}
}
}