Sic04/FrameworkLocal/RTEquipmentLibrary/HardwareUnits/MachineVision/Keyence/KeyenceCVX300F.cs

565 lines
16 KiB
C#
Raw Normal View History

2022-09-19 09:16:33 +08:00
using Aitex.Core.RT.DataCenter;
using Aitex.Core.RT.Device;
using Aitex.Core.RT.Event;
using Aitex.Core.RT.Log;
using Aitex.Core.RT.OperationCenter;
using Aitex.Core.RT.SCCore;
using Aitex.Core.Util;
using MECF.Framework.Common.Communications;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading;
namespace MECF.Framework.RT.EquipmentLibrary.HardwareUnits.MachineVision.Keyence
{
public class KeyenceCVX300F : BaseDevice, IConnection, IDevice
{
private KeyenceCVX300FConnection _connection;
private bool _isOn;
private bool _activeMonitorStatus;
private int _errorCode;
private string _lastError = string.Empty;
//private RD_TRIG _trigPumpOnOff = new RD_TRIG();
//private R_TRIG _trigError = new R_TRIG();
//private R_TRIG _trigOverTemp = new R_TRIG();
//private R_TRIG _trigWarningMessage = new R_TRIG();
private R_TRIG _trigCommunicationError = new R_TRIG();
private R_TRIG _trigRetryConnect = new R_TRIG();
uint iCurrentOper = 0xff;
List<byte> liReceivedData = new List<byte>();
byte bEnd = 0x0d;
//bool bStaGood = true;
//bool bCanBeat = false;
//int iBeatTimes = 0;
private int _iArea = 0;
public string _sResult;
//
private PeriodicJob _thread;
private LinkedList<HandlerBase> _lstHandler = new LinkedList<HandlerBase>();
private object _locker = new object();
private bool _enableLog = true;
private string _scRoot;
private string _strCmd;
#region
public string Address
{
get; set;
}
public bool IsConnected
{
get
{
return _connection != null && _connection.IsConnected;
}
}
//属性
public bool AlarmStatus { get; set; }
public bool PositionComplete { get; set; }
public bool MotorBusy { get; set; }
//
public bool IsBusy { get; set; }
//public bool IsStbOff { get; set; } //StbOff消息是否发送
public int AreaData
{
get { return _iArea; }
}
#endregion
public bool Connect()
{
return true;
}
public bool Disconnect()
{
return true;
}
public KeyenceCVX300F(string module, string scRoot, string name) : base(module, name, name, name)
{
_scRoot = scRoot;
_activeMonitorStatus = true;
//
}
public bool Initialize()
{
// string portName = SC.GetStringValue($"{_scRoot}.{Module}.{Name}.Address");
string sAddress = SC.GetStringValue($"{Name}.Address");
Address = sAddress;
_enableLog = SC.GetValue<bool>($"{Name}.EnableLogMessage");
_connection = new KeyenceCVX300FConnection(sAddress);
_connection.EnableLog(_enableLog);
//
_sResult = "";
//
if (_connection.Connect())
{
EV.PostInfoLog(Module, $"{Module}.{Name} connected");
}
//设置属性
this.SetAttr();
//设置操作
this.SetOP();
//
_thread = new PeriodicJob(200, OnTimer, $"{Name} MonitorHandler", true);
//
//this.InitMachine();
//
ConnectionManager.Instance.Subscribe($"{Name}", this);
//SetServoOn();
return true;
}
/// <summary>
/// 设置属性
/// </summary>
private void SetAttr()
{
//DATA.Subscribe($"{Module}.{Name}.Area", () => _iArea);
DATA.Subscribe($"{Module}.{Name}.Result", () => this._sResult);
}
/// <summary>
/// 设置操作
/// </summary>
private void SetOP()
{
//读取面积
//OP.Subscribe($"{Module}.{Name}.CVXCheckArea", (cmd, param) =>
//{
// //Set("T1","T1");
// //EV.PostInfoLog(Module, $"{Name} Get area data.");
// return true;
//});
//读取结果
OP.Subscribe($"{Module}.{Name}.GetResult", (cmd, param) =>
{
GetResult(Convert.ToInt32(param[0]));
//
return true;
});
//转至运行模式
OP.Subscribe($"{Module}.{Name}.RunR0", (cmd, param) =>
{
RunR0();
return true;
});
//清除结果
OP.Subscribe($"{Module}.{Name}.ClearResult", (cmd, param) =>
{
this.ClearResult();
return true;
});
}
public void ClearResult()
{
this._sResult = "";
}
/// <summary>
/// 转到运行模式
/// </summary>
public void RunR0()
{
Set("R0", "R0");
EV.PostInfoLog(Module, $"{Name} Run R0 command.");
}
/// <summary>
/// 获取拍照比对结果
/// </summary>
/// <param name="iConId">执行条件编号</param>
public void GetResult(int iConId)
{
SetExecCond(iConId);
//this._strCmd = param[0] as string;
//if (this._strCmd.Length > 0)
//{
// Set(this._strCmd, this._strCmd);
// EV.PostInfoLog(Module, $"{Name} Get result.");
//}
//
//Set("T1", "T1");
EV.PostInfoLog(Module, $"{Name} Get result.");
}
/// <summary>
/// 设置输出文件名
/// </summary>
/// <param name="sFileName"></param>
public void SetFileName(string sFileName)
{
string sCmd = "STW,1," + sFileName.Trim();//1为相机内文件名编号相机输出时调用编号
Set("STW", sCmd);
EV.PostInfoLog(Module, $"{Name} Set file name:" + sFileName);
}
/// <summary>
/// 写入执行条件:EXW,n
/// </summary>
/// <param name="iConId">条件编号</param>
public void SetExecCond(int iConId)
{
string sCmd = "EXW," + iConId.ToString();//执行条件编号现在是点1处使用条件1点2处使用条件2
Set("EXW", sCmd);
EV.PostInfoLog(Module, $"{Name} Set condition no.");
}
/// <summary>
/// 加入命令队列
/// </summary>
/// <param name="strCmd">命令 Ascii格式</param>
public void Set(string name, string strCmd)
{
lock (_locker)
{
_lstHandler.Clear();
if (_connection.IsBusy)
{
_connection.ForceClear();
}
List<byte> liCmd = Encoding.ASCII.GetBytes(strCmd).ToList<byte>();
liCmd.Add(0x0d); //CR
//liCmd.Add(0x0a); //LF 不可颠倒
byte[] bCmd = liCmd.ToArray();
//_lstHandler.AddLast(new HwAlignerGuideQueryHandler(this, strCmd, bCmd));
_lstHandler.AddLast(new KeyenceCVX300FSetHandler(this, name, bCmd));
}
}
public int _connecteTimes { get; set; }
private bool OnTimer()
{
try
{
//
_connection.MonitorTimeout();
//若断,重连
if ((!_connection.IsConnected) || _connection.IsCommunicationError)
{
lock (_locker)
{
//_trigSevroOn.RST = true;
//IsBusy = false;
_lstHandler.Clear();
}
//
_trigRetryConnect.CLK = _connection.IsConnected; //不可重复置值否则Q会有变化
if (_connection.Connect())
{
//
//if (_trigRetryConnect.Q)
//{
EV.PostInfoLog(Module, $"{Module}.{Name} connected");
LOG.Write($"{Module}.{Name} connected");
//}
//转至运行模式,此命令可以重入
this.RunR0();
this.SetFileName("sic");
}
else
{
if (_trigRetryConnect.Q)
{
EV.PostInfoLog(Module, $"Trying to connect {Module}.{Name} with address: {_connection.Address}");
LOG.Write($"Trying to connect {Module}.{Name} with address: {_connection.Address}");
}
}
}
//处理命令队列
HandlerBase handler = null;
if (!_connection.IsBusy)
{
lock (_locker)
{
if (_lstHandler.Count == 0 && _activeMonitorStatus && !IsBusy)
{
//Query();
}
if (_lstHandler.Count > 0)
{
handler = _lstHandler.First.Value;
_lstHandler.RemoveFirst();
}
}
if (handler != null)
{
_connection.Execute(handler);
}
}
//
return true;
}
catch (Exception ex)
{
LOG.Write(ex);
}
return true;
}
internal void NoteError()
{
}
public void Monitor()
{
try
{
_connection.EnableLog(_enableLog);
//if (_connecteTimes < 4) return;
_trigCommunicationError.CLK = _connection.IsCommunicationError;
if (_trigCommunicationError.Q)
{
EV.PostAlarmLog(Module, $"{Module}.{Name} communication error, {_connection.LastCommunicationError}");
}
}
catch (Exception ex)
{
LOG.Write(ex);
}
}
public void Terminate()
{
try
{
if (_connection != null)
{
_connection.Disconnect();
_connection = null;
}
}
catch (Exception ex)
{
LOG.Write(ex);
}
}
public void Reset()
{
//
_connecteTimes = 0;
_connection.SetCommunicationError(false, "");//这里重置了CommunicationError 就是去了OnTimer里面的重连的触发所以需要另设变量以触发之(使用timeout来触发的情况
_enableLog = SC.GetValue<bool>($"{Name}.EnableLogMessage");
_trigCommunicationError.RST = true;
_trigRetryConnect.RST = true;
//
}
public void SetActiveMonitor(bool active)
{
_activeMonitorStatus = active;
}
//internal void NoteOnOff(bool isOn)
//{
// _isOn = isOn;
//}
public bool _PraseData(string name, byte[] buffer)
{
bool bRes = false;
//
try
{
this.bEnd = 0x0d;
this.liReceivedData.AddRange(buffer);
List<byte> liData = new List<byte>();
int iIndex = this.liReceivedData.LastIndexOf(bEnd);
//int iIndex = this.liReceivedData.IndexOf(bEnd);
if (iIndex > 0)
{
liData.AddRange(this.liReceivedData.GetRange(0, iIndex + 1));
this.liReceivedData.RemoveRange(0, iIndex + 1);
}
else
{
return false;
}
string sAnswer = Encoding.ASCII.GetString(liData.ToArray());
//string sAnswer = Encoding.ASCII.GetString(buffer);
//返回一次 "T1\r" ,再次返回 "T1\r00004422,0\r"
string[] sCmds = sAnswer.Split('\n', '\r');
foreach (string sOneCmd in sCmds)
{
if (sOneCmd.Length > 0 && sOneCmd.Trim().CompareTo(name) != 0)
{
//bRes = this.DoOneCmd(name, sOneCmd);
}
}
}
catch (Exception ex)
{
string sEx = $"{Module}.{Name} Exception:" + ex.Message;
EV.PostAlarmLog(Module, sEx);
LOG.Write(sEx);
}
//
return bRes;
}
public bool PraseData(string name, byte[] buffer)
{
//
string sCmdBack = Encoding.ASCII.GetString(buffer);
bool bRes = false;
//
if (sCmdBack.Trim().Length > 0)
{
//
if (name.CompareTo("T1") == 0)
{
if (sCmdBack.CompareTo("T1\r") == 0)
{
bRes = false;
}
else
{
bool bResult = sCmdBack.Replace("T1\r", "").Contains("0");
//
if (bResult)
{
this._sResult = "OK";
}
else
{
this._sResult = "NG";
}
bRes = true;
}
}
else if (name.CompareTo("EXW") == 0)
{
Set("T1", "T1");
bRes = true;
}
else
{
if (sCmdBack.Contains("ER,"))
{
EV.PostWarningLog(Module, "Keyence CCD camera get an error answer.");
}
bRes = true;
}
}
//
return bRes;
}
//public void SetErrorCode(int errorCode)
//{
// _errorCode = errorCode;
//}
//public void SetError(string reason)
//{
// _trigWarningMessage.CLK = true;
// if (_trigWarningMessage.Q)
// {
// EV.PostWarningLog(Module, $"{Module}.{Name} error, {reason}");
// }
//}
private static byte[] ModRTU_CRC(byte[] buffer)
{
ushort crc = 0xFFFF;
// var buf = System.Text.Encoding.UTF8.GetBytes(String.Join(Environment.NewLine, buffer));
var buf = buffer;
var len = buffer.Length;
for (var pos = 0; pos < len; pos++)
{
crc ^= buf[pos]; // XOR byte into least sig. byte of crc
for (var i = 8; i != 0; i--)
// Loop over each bit
if ((crc & 0x0001) != 0)
{
// If the LSB is set
crc >>= 1; // Shift right and XOR 0xA001
crc ^= 0xA001;
}
else // Else LSB is not set
{
crc >>= 1; // Just shift right
}
}
// Note, this number has low and high bytes swapped, so use it accordingly (or swap bytes)
return BitConverter.GetBytes(crc);
}
}
}