using Aitex.Core.RT.Event;
using Aitex.Core.RT.Routine;
using Aitex.Core.RT.SCCore;
using MECF.Framework.Common.Equipment;
using System;
using System.Diagnostics;
namespace Mainframe.UnLoads
{
public class UnLoadPrepareTransferRoutine : UnLoadBaseRoutine
{
enum RoutineStep
{
CheckForelinePressure,
RequestPump,
RequestPumpDelay,
SlowPump,
CloseSlowValve,
FastPump,
PumpDelay,
CloseFastValve,
Delay,
SlowVent,
CloseSlowVentValve,
TimeDelay1,
TimeDelay2,
}
private double _pumpSwitchPressure = 100;
private int _slowPumpTimeout = 100;
private int _fastPumpTimeout = 100;
private int _slowVentTimeout = 100;
private double _targetPressure;
private double _llVacPressure = 0;
private double _balancePressureDiff = 0;
private double _pumpBasePressure = 0;
private int _pumpDelayTime;
public UnLoadPrepareTransferRoutine()
{
Module = ModuleName.UnLoad.ToString();
Name = "PrepareTransfer";
}
public override Result Start(params object[] objs)
{
Reset();
_targetPressure = SC.GetValue<double>("TM.PressureBalance.BalancePressure");
_llVacPressure = SC.GetValue<double>("UnLoad.VacuumPressureBase");
_pumpBasePressure = SC.GetValue<double>("UnLoad.Purge.PumpBasePressure");
_balancePressureDiff = SC.GetValue<double>("TM.PressureBalance.BalanceMaxDiffPressure");
_pumpSwitchPressure = SC.GetValue<double>("UnLoad.Pump.SlowFastPumpSwitchPressure");
_slowPumpTimeout = SC.GetValue<int>("UnLoad.Pump.SlowPumpTimeout");
_fastPumpTimeout = SC.GetValue<int>("UnLoad.Pump.FastPumpTimeout");
_slowVentTimeout = SC.GetValue<int>("UnLoad.Vent.SlowVentTimeout");
_pumpDelayTime = SC.GetValue<int>("UnLoad.Purge.PumpDelayTime");
//PrepareTrasfer需要把压力调到VacuumBasePressure以下
if (_targetPressure > _llVacPressure)
{
_targetPressure = _llVacPressure;
}
string reason;
if (!UnLoadDevice.SetFastVentValve(false, out reason) || !UnLoadDevice.SetSlowVentValve(false, out reason))
{
EV.PostAlarmLog(Module, $"Can not turn off valves, {reason}");
return Result.FAIL;
}
if (!UnLoadDevice.SetFastPumpValve(false, out reason) || !UnLoadDevice.SetSlowPumpValve(false, out reason))
{
EV.PostAlarmLog(Module, $"Can not turn off valves, {reason}");
return Result.FAIL;
}
bool isAtmMode = SC.GetValue<bool>("System.IsATMMode");
if (isAtmMode)
{
EV.PostInfoLog(Module, $"system in atm mode, {UnLoadDevice.Module} pump skipped");
return Result.DONE;
}
if (!UnLoadDevice.CheckLidClose())
{
EV.PostAlarmLog(Module, $"Can not pump, door is open");
return Result.FAIL;
}
if (!TMDevice.CheckSlitValveClose(ModuleHelper.Converter(UnLoadDevice.Module)))
{
EV.PostAlarmLog(Module, $"LoadLock Can not servo to pressure, slit valve is open");
return Result.FAIL;
}
//if (Math.Abs(_targetPressure - UnLoadDevice.ChamberPressure) < _balancePressureDiff && UnLoadDevice.CheckVacuum())
//{
// return Result.DONE;
//}
Notify("Start");
return Result.RUN;
}
public override Result Monitor()
{
try
{
TimeDelay((int)RoutineStep.TimeDelay1, 1);
SlowPump((int)RoutineStep.SlowPump, _pumpSwitchPressure, _slowPumpTimeout);
FastPump((int)RoutineStep.FastPump, _pumpBasePressure, _fastPumpTimeout);
TimeDelay((int)RoutineStep.TimeDelay2, _pumpDelayTime);
CloseFastPumpValve((int)RoutineStep.CloseFastValve);
CloseSlowPumpValve((int)RoutineStep.CloseSlowValve);
SlowVent((int)RoutineStep.SlowVent, _targetPressure - 5, _slowVentTimeout);
CloseVentValve((int)RoutineStep.CloseSlowVentValve);
}
catch (RoutineBreakException)
{
return Result.RUN;
}
catch (RoutineFaildException)
{
return Result.FAIL;
}
Notify("Finished");
return Result.DONE;
}
public override void Abort()
{
UnLoadDevice.SetSlowPumpValve(false, out _);
UnLoadDevice.SetFastPumpValve(false, out _);
}
}
}