parent
d4a2d4b252
commit
c18ffff29d
|
@ -34,7 +34,7 @@ namespace SicModules.TMs
|
|||
//private IoPressureMeter3 _forelineGuage_PS7;
|
||||
private IoPressureMeter3 _chamberGuage_TM;
|
||||
private IoPressureMeter3 _loadLockGuage_PT3;
|
||||
private IoPressureMeter3 _unLoadGuage_PT3;
|
||||
private IoPressureMeter3 _unLoadGuage;
|
||||
private IoPressureMeter3 _pm1Pressure2;
|
||||
private IoPressureMeter3 _pm2Pressure2;
|
||||
|
||||
|
@ -75,7 +75,7 @@ namespace SicModules.TMs
|
|||
{
|
||||
get
|
||||
{
|
||||
return _unLoadGuage_PT3.Value;
|
||||
return _unLoadGuage.Value;
|
||||
}
|
||||
}
|
||||
|
||||
|
@ -162,7 +162,7 @@ namespace SicModules.TMs
|
|||
_chamberGuage_TM = DEVICE.GetDevice<IoPressureMeter3>("TM.TMPressure");
|
||||
//_forelineGuage_PS7 = DEVICE.GetDevice<IoPressureMeter3>("TM.ForelinePressure");
|
||||
_loadLockGuage_PT3 = DEVICE.GetDevice<IoPressureMeter3>("TM.LLPressure");
|
||||
_unLoadGuage_PT3 = DEVICE.GetDevice<IoPressureMeter3>("TM.UnLoadPressure");
|
||||
_unLoadGuage = DEVICE.GetDevice<IoPressureMeter3>("TM.UnLoadPressure");
|
||||
_pm1Pressure2 = DEVICE.GetDevice<IoPressureMeter3>("TM.PM1Pressure2");
|
||||
_pm2Pressure2 = DEVICE.GetDevice<IoPressureMeter3>("TM.PM2Pressure2");
|
||||
|
||||
|
|
|
@ -255,8 +255,6 @@ namespace SicModules.TMs
|
|||
|
||||
InitScChangeCallback();
|
||||
|
||||
|
||||
|
||||
return base.Initialize();
|
||||
}
|
||||
|
||||
|
@ -580,10 +578,10 @@ namespace SicModules.TMs
|
|||
|
||||
private void InitData()
|
||||
{
|
||||
DATA.Subscribe($"{Name}.IsPressureAbs_TM_PMA_DValue_In50", () => IsPressureAbs_TM_PMA_DValue_In50);
|
||||
DATA.Subscribe($"{Name}.IsPressureAbs_TM_PMB_DValue_In50", () => IsPressureAbs_TM_PMB_DValue_In50);
|
||||
DATA.Subscribe($"{Name}.IsPressureAbs_TM_Unload_DValue_In50", () => IsPressureAbs_TM_Unload_DValue_In50);
|
||||
DATA.Subscribe($"{Name}.IsPressureAbs_TM_Load_DValue_In50", () => IsPressureAbs_TM_Load_DValue_In50);
|
||||
DATA.Subscribe($"{Name}.IsPressureAbs_TM_PMA_DValue_In50", () => IsPressureAbs_TM_PMA_DValue_In50,Aitex.Core.Util.SubscriptionAttribute.FLAG.IgnoreSaveDB);
|
||||
DATA.Subscribe($"{Name}.IsPressureAbs_TM_PMB_DValue_In50", () => IsPressureAbs_TM_PMB_DValue_In50, Aitex.Core.Util.SubscriptionAttribute.FLAG.IgnoreSaveDB);
|
||||
DATA.Subscribe($"{Name}.IsPressureAbs_TM_Unload_DValue_In50", () => IsPressureAbs_TM_Unload_DValue_In50, Aitex.Core.Util.SubscriptionAttribute.FLAG.IgnoreSaveDB);
|
||||
DATA.Subscribe($"{Name}.IsPressureAbs_TM_Load_DValue_In50", () => IsPressureAbs_TM_Load_DValue_In50, Aitex.Core.Util.SubscriptionAttribute.FLAG.IgnoreSaveDB);
|
||||
|
||||
DATA.Subscribe($"{Name}.Status", () => StringFsmStatus);
|
||||
DATA.Subscribe($"{Name}.IsOnline", () => IsOnline);
|
||||
|
|
|
@ -329,7 +329,7 @@ namespace SicModules.UnLoads
|
|||
DATA.Subscribe($"{Name}.CurrentRoutineLoopTotal", () => CurrentRoutineLoopTotal, SubscriptionAttribute.FLAG.IgnoreSaveDB);
|
||||
DATA.Subscribe($"{Name}.RemainedCoolingTime", () => _unloadCoolingRoutine.GetRemainedTime(), SubscriptionAttribute.FLAG.IgnoreSaveDB);
|
||||
|
||||
DATA.Subscribe($"{Name}.AtATM", () => { return _unLoadDevice.CheckAtm(); });
|
||||
//DATA.Subscribe($"{Name}.AtATM", () => { return _unLoadDevice.CheckAtm(); });
|
||||
|
||||
DATA.Subscribe($"{Name}.UnderVAC", () =>
|
||||
{
|
||||
|
|
|
@ -51,5 +51,5 @@ using System.Windows;
|
|||
// 可以指定所有值,也可以使用以下所示的 "*" 预置版本号和修订号
|
||||
// 方法是按如下所示使用“*”: :
|
||||
|
||||
[assembly: AssemblyVersion("1.1.31.47")]
|
||||
[assembly: AssemblyVersion("23.9.28.2")]
|
||||
[assembly: AssemblyInformationalVersion("自动通用版(有EFEM)")]
|
|
@ -2,6 +2,16 @@
|
|||
# Sic Auto-GE 系统更新历史记录
|
||||
Auto-GE 自动通用版(适用有EFEM设备)
|
||||
|
||||
## Version 23.9.28.2
|
||||
**2023-09-28**
|
||||
|
||||
- Bug修复
|
||||
- 新增data不保存数据库
|
||||
|
||||
- 新特性
|
||||
- interlock表更新 不同腔体开门时需要判断两个腔体压差在范围内
|
||||
------
|
||||
|
||||
## Version 1.1.31.46
|
||||
**2023-09-15**
|
||||
|
||||
|
|
|
@ -54,5 +54,5 @@ using System.Windows;
|
|||
// You can specify all the values or you can default the Build and Revision Numbers
|
||||
// by using the '*' as shown below:
|
||||
|
||||
[assembly: AssemblyVersion("1.1.31.47")]
|
||||
[assembly: AssemblyVersion("23.9.28.2")]
|
||||
[assembly: AssemblyInformationalVersion("自动通用版(有EFEM)")]
|
||||
|
|
Loading…
Reference in New Issue