using Aitex.Core.Common.DeviceData;
|
|
using Aitex.Core.RT.DataCenter;
|
|
using Aitex.Core.RT.Event;
|
|
using Aitex.Core.RT.IOCore;
|
|
using Aitex.Core.RT.Log;
|
|
using Aitex.Core.RT.OperationCenter;
|
|
using Aitex.Core.RT.SCCore;
|
|
using Aitex.Core.Util;
|
|
using Aitex.Core.Utilities;
|
|
using System;
|
|
using System.Collections.Generic;
|
|
using System.Threading;
|
|
using System.Xml;
|
|
|
|
namespace Aitex.Core.RT.Device.Devices
|
|
{
|
|
public class IoThrottleValve2 : BaseDevice, IDevice
|
|
{
|
|
public PressureCtrlMode PressureMode
|
|
{
|
|
get
|
|
{
|
|
if (_aoPressureMode != null)
|
|
{
|
|
foreach (var ioMode in _ctrlModeIoValue)
|
|
{
|
|
if (_isFloatAioType)
|
|
{
|
|
if ((int)_aoPressureMode.FloatValue == ioMode.Value)
|
|
{
|
|
return ioMode.Key;
|
|
}
|
|
}
|
|
else
|
|
{
|
|
if (_aoPressureMode.Value == ioMode.Value)
|
|
{
|
|
return ioMode.Key;
|
|
}
|
|
}
|
|
|
|
}
|
|
return PressureCtrlMode.Undefined;
|
|
}
|
|
|
|
return PressureCtrlMode.Undefined;
|
|
}
|
|
set
|
|
{
|
|
if (_isFloatAioType)
|
|
_aoPressureMode.FloatValue = _ctrlModeIoValue[value];
|
|
else
|
|
{
|
|
_aoPressureMode.Value = (short)_ctrlModeIoValue[value];
|
|
}
|
|
}
|
|
}
|
|
|
|
public PressureCtrlMode ControlModeFeedback
|
|
{
|
|
get
|
|
{
|
|
if (_aiPressureMode != null)
|
|
{
|
|
foreach (var ioMode in _ctrlModeIoValue)
|
|
{
|
|
if (_isFloatAioType)
|
|
{
|
|
if ((int)_aiPressureMode.FloatValue == ioMode.Value)
|
|
{
|
|
return ioMode.Key;
|
|
}
|
|
}
|
|
else
|
|
{
|
|
if (_aiPressureMode.Value == ioMode.Value)
|
|
{
|
|
return ioMode.Key;
|
|
}
|
|
}
|
|
|
|
}
|
|
return PressureCtrlMode.Undefined;
|
|
}
|
|
|
|
return PressureCtrlMode.Undefined;
|
|
}
|
|
}
|
|
|
|
public bool TVValveEnable
|
|
{
|
|
get
|
|
{
|
|
if (_doTVValveEnable!=null)
|
|
{
|
|
return _doTVValveEnable.Value;
|
|
}
|
|
return false;
|
|
}
|
|
}
|
|
|
|
public float PositionSetpoint
|
|
{
|
|
get
|
|
{
|
|
return _aoPositionSetPoint == null ? 0 : (_isFloatAioType? _aoPositionSetPoint.FloatValue: _aoPositionSetPoint.Value);
|
|
}
|
|
set
|
|
{
|
|
if (_isFloatAioType)
|
|
{
|
|
_aoPositionSetPoint.FloatValue = value;
|
|
}
|
|
else
|
|
{
|
|
_aoPositionSetPoint.Value = (short)value;
|
|
}
|
|
}
|
|
}
|
|
|
|
public float PositionFeedback
|
|
{
|
|
get
|
|
{
|
|
return _aiPositionFeedback == null ? 0 : (_isFloatAioType ? _aiPositionFeedback.FloatValue: _aiPositionFeedback.Value);
|
|
}
|
|
}
|
|
|
|
public float PressureSetpoint
|
|
{
|
|
get
|
|
{
|
|
return _aoPressureSetPoint == null ? 0 : (_isFloatAioType ? _aoPressureSetPoint.FloatValue:_aoPressureSetPoint.Value);
|
|
}
|
|
set
|
|
{
|
|
if (_isFloatAioType)
|
|
{
|
|
_aoPressureSetPoint.FloatValue = value;
|
|
}
|
|
else
|
|
{
|
|
_aoPressureSetPoint.Value = (short)value;
|
|
}
|
|
}
|
|
}
|
|
|
|
public float PressureFeedback
|
|
{
|
|
get
|
|
{
|
|
return _aiPressureFeedback == null ? 0 : (_isFloatAioType ? _aiPressureFeedback.FloatValue:_aiPressureFeedback.Value);
|
|
}
|
|
}
|
|
|
|
private float _pressureSetPointByUse;
|
|
public float PressureSetpointByUse
|
|
{
|
|
get
|
|
{
|
|
return _pressureSetPointByUse;
|
|
}
|
|
set
|
|
{
|
|
_pressureSetPointByUse = value;
|
|
}
|
|
}
|
|
|
|
private float _positionSetPointByUse;
|
|
public float PositionSetpointByUse
|
|
{
|
|
get
|
|
{
|
|
return _positionSetPointByUse;
|
|
}
|
|
set
|
|
{
|
|
_positionSetPointByUse = value;
|
|
}
|
|
}
|
|
|
|
public float PositionDefaultValue
|
|
{
|
|
get
|
|
{
|
|
if (_positionDefaultValue != null)
|
|
{
|
|
return (float)_positionDefaultValue.DoubleValue;
|
|
}
|
|
else
|
|
{
|
|
return 0;
|
|
}
|
|
}
|
|
}
|
|
|
|
private float _pressureDefaultValue2;
|
|
public float PressureDefaultValue
|
|
{
|
|
get
|
|
{
|
|
//return _pressureDefaultValue2;
|
|
if (_pressureDefaultValue != null)
|
|
{
|
|
return (float)_pressureDefaultValue.DoubleValue;
|
|
}
|
|
else
|
|
{
|
|
return 1100;
|
|
}
|
|
}
|
|
//set
|
|
//{
|
|
// _pressureDefaultValue2 = value;
|
|
//}
|
|
}
|
|
|
|
|
|
private SCConfigItem _positionDefaultValue;
|
|
private SCConfigItem _pressureDefaultValue;
|
|
|
|
private DeviceTimer _closeTimer = new DeviceTimer();
|
|
private DeviceTimer _rampTimer = new DeviceTimer();
|
|
private double _rampTarget;
|
|
private double _rampInitValue;
|
|
private int _rampTime;
|
|
|
|
|
|
private DeviceTimer _rampTimer1 = new DeviceTimer();
|
|
private double _rampTarget1;
|
|
private double _rampInitValue1;
|
|
private int _rampTime1;
|
|
|
|
private AITThrottleValveData DeviceData
|
|
{
|
|
get
|
|
{
|
|
AITThrottleValveData data = new AITThrottleValveData()
|
|
{
|
|
Module = Module,
|
|
DeviceName = Name,
|
|
DeviceSchematicId = DeviceID,
|
|
DisplayName = Display,
|
|
Mode = (int)ControlModeFeedback,
|
|
PositionFeedback = PositionFeedback,
|
|
PositionSetPoint = PositionSetpointByUse,
|
|
PositionSetPointCurrent = PositionSetpoint,
|
|
|
|
PressureFeedback = PressureFeedback,
|
|
PressureSetPoint = PressureSetpointByUse,
|
|
PressureSetPointCurrent = PressureSetpoint,
|
|
|
|
TVEnable = TVValveEnable,
|
|
|
|
MaxValuePosition = 100,
|
|
MaxValuePressure = _unitPressure == "mbar" ? 1500 : 1500,
|
|
|
|
UnitPressure = _unitPressure,
|
|
};
|
|
|
|
return data;
|
|
}
|
|
}
|
|
|
|
private AIAccessor _aiPressureMode = null;
|
|
|
|
private AOAccessor _aoPressureMode = null;
|
|
|
|
private AIAccessor _aiPositionFeedback = null;
|
|
|
|
private AOAccessor _aoPositionSetPoint = null;
|
|
|
|
private AIAccessor _aiPressureFeedback = null;
|
|
|
|
private AOAccessor _aoPressureSetPoint = null;
|
|
|
|
private DOAccessor _doTVValveEnable = null;
|
|
|
|
private string _unitPressure;
|
|
|
|
private Dictionary<PressureCtrlMode, int> _ctrlModeIoValue = new Dictionary<PressureCtrlMode, int>();
|
|
|
|
private bool _isFloatAioType = false;
|
|
private R_TRIG _setTvCloseTrig = new R_TRIG();
|
|
|
|
public IoThrottleValve2(string module, XmlElement node, string ioModule = "")
|
|
{
|
|
var attrModule = node.GetAttribute("module");
|
|
base.Module = string.IsNullOrEmpty(attrModule) ? module : attrModule;
|
|
|
|
base.Name = node.GetAttribute("id");
|
|
base.Display = node.GetAttribute("display");
|
|
base.DeviceID = node.GetAttribute("schematicId");
|
|
|
|
string scBasePath = node.GetAttribute("scBasePath");
|
|
if (string.IsNullOrEmpty(scBasePath))
|
|
scBasePath = $"{Module}.{Name}";
|
|
else
|
|
{
|
|
scBasePath = scBasePath.Replace("{module}", Module);
|
|
}
|
|
|
|
_unitPressure = node.GetAttribute("unit");
|
|
_isFloatAioType = !string.IsNullOrEmpty(node.GetAttribute("aioType")) && (node.GetAttribute("aioType") == "float");
|
|
|
|
_aiPressureMode = ParseAiNode("aiStatus", node, ioModule);
|
|
_aoPressureMode = ParseAoNode("aoPressureMode", node, ioModule);
|
|
|
|
_aiPositionFeedback = ParseAiNode("aiPositionFeedback", node, ioModule);
|
|
_aoPositionSetPoint = ParseAoNode("aoPositionSetPoint", node, ioModule);
|
|
_aiPressureFeedback = ParseAiNode("aiPressureFeedback", node, ioModule);
|
|
_aoPressureSetPoint = ParseAoNode("aoPressureSetPoint", node, ioModule);
|
|
_doTVValveEnable = ParseDoNode("doTVValveEnable", node, ioModule);
|
|
|
|
_positionDefaultValue = ParseScNode("positionDefaultValue", node, ioModule, $"{scBasePath}.ThrottlePositionDefaultValue");
|
|
_pressureDefaultValue = ParseScNode("pressureDefaultValue", node, ioModule, $"{scBasePath}.ThrottlePressureDefaultValue");
|
|
|
|
EnumLoop<PressureCtrlMode>.ForEach(x => _ctrlModeIoValue[x] = -1);
|
|
|
|
if (!string.IsNullOrEmpty(node.GetAttribute("modeValuePressure")))
|
|
{
|
|
_ctrlModeIoValue[PressureCtrlMode.TVPressureCtrl] = int.Parse(node.GetAttribute("modeValuePressure"));
|
|
}
|
|
if (!string.IsNullOrEmpty(node.GetAttribute("modeValuePosition")))
|
|
{
|
|
_ctrlModeIoValue[PressureCtrlMode.TVPositionCtrl] = int.Parse(node.GetAttribute("modeValuePosition"));
|
|
}
|
|
if (!string.IsNullOrEmpty(node.GetAttribute("modeValueOpen")))
|
|
{
|
|
_ctrlModeIoValue[PressureCtrlMode.TVOpen] = int.Parse(node.GetAttribute("modeValueOpen"));
|
|
}
|
|
if (!string.IsNullOrEmpty(node.GetAttribute("modeValueClose")))
|
|
{
|
|
_ctrlModeIoValue[PressureCtrlMode.TVClose] = int.Parse(node.GetAttribute("modeValueClose"));
|
|
}
|
|
//PressureDefaultValue = (float)_pressureDefaultValue.DoubleValue;
|
|
}
|
|
|
|
|
|
public bool Initialize()
|
|
{
|
|
DATA.Subscribe($"{Module}.{Name}.DeviceData", () => DeviceData);
|
|
|
|
DATA.Subscribe($"{Module}.{Name}.PositionSetPoint", () => PositionSetpoint);
|
|
DATA.Subscribe($"{Module}.{Name}.PositionFeedback", () => PositionFeedback);
|
|
DATA.Subscribe($"{Module}.{Name}.PressureSetPoint", () => PressureSetpoint);
|
|
DATA.Subscribe($"{Module}.{Name}.PressureFeedback", () => PressureFeedback);
|
|
DATA.Subscribe($"{Module}.{Name}.Mode", () => ControlModeFeedback);
|
|
DATA.Subscribe($"{Module}.{Name}.TVValveEnable", () => TVValveEnable);
|
|
|
|
OP.Subscribe($"{Module}.{Name}.{AITThrottleValveOperation.SetMode}", SetMode);
|
|
|
|
OP.Subscribe($"{Module}.{Name}.{AITThrottleValveOperation.SetPosition}", SetPosition);
|
|
|
|
OP.Subscribe($"{Module}.{Name}.{AITThrottleValveOperation.SetPressure}", SetPressure);
|
|
|
|
OP.Subscribe($"{Module}.{Name}.SetPositionToZero", SetPositionToZero);
|
|
|
|
OP.Subscribe($"{Module}.{Name}.SetTVEnableRoutine", SetTVEnableRoutine);
|
|
|
|
OP.Subscribe($"{Module}.{Name}.SetTVValveEnable", (function, args) =>
|
|
{
|
|
bool bOn = Convert.ToBoolean((string)args[0]);
|
|
SetTVEnable(bOn, out string reason);
|
|
return true;
|
|
});
|
|
|
|
return true;
|
|
}
|
|
|
|
|
|
|
|
public bool SetMode(PressureCtrlMode mode, out string reason)
|
|
{
|
|
reason = String.Empty;
|
|
if (mode == ControlModeFeedback)
|
|
{
|
|
return true;
|
|
}
|
|
if (mode == PressureCtrlMode.TVClose)
|
|
{
|
|
_rampTimer.Stop();
|
|
_rampTimer1.Stop();
|
|
reason = $"{Display} set to {mode}";
|
|
PressureMode = mode;
|
|
}
|
|
else
|
|
{
|
|
if (!_rampTimer.IsIdle() || !_rampTimer1.IsIdle())
|
|
{
|
|
//在压力正在调节过程中不允许切换模式
|
|
reason = "Can not set mode while pressure is ramping!";
|
|
return false;
|
|
}
|
|
|
|
reason = $"{Display} set to {mode}";
|
|
PressureMode = mode;
|
|
}
|
|
|
|
EV.PostInfoLog(Module, reason);
|
|
|
|
return true;
|
|
}
|
|
|
|
private bool SetMode(out string reason, int time, object[] param)
|
|
{
|
|
return SetMode((PressureCtrlMode)Enum.Parse(typeof(PressureCtrlMode), (string)param[0], true),
|
|
out reason);
|
|
}
|
|
|
|
//private bool SetPosition(float position, out string reason)
|
|
//{
|
|
// PositionSetpoint = position;
|
|
|
|
// reason = $"{Display} position set to {position}";
|
|
|
|
// EV.PostInfoLog(Module, reason);
|
|
|
|
// return true;
|
|
//}
|
|
|
|
public bool SetPosition(out string reason, int time, object[] param)
|
|
{
|
|
reason = String.Empty;
|
|
if (ControlModeFeedback != PressureCtrlMode.TVPositionCtrl)
|
|
{
|
|
reason = "TV is not in position control mode";
|
|
return false;
|
|
}
|
|
|
|
PositionSetpointByUse = (float)Convert.ToDouble(param[0]);
|
|
|
|
if (time > 0)
|
|
{
|
|
_rampTimer1.Stop();
|
|
Ramp(Convert.ToDouble(param[0]), time);
|
|
}
|
|
else
|
|
{
|
|
_rampTimer1.Stop();
|
|
double rate = SC.GetValue<double>($"PM.{Module}.ThrottlePositionRate");
|
|
RampByRatePosition(Convert.ToDouble(param[0]), rate);
|
|
}
|
|
return true;
|
|
}
|
|
|
|
public bool SetPressure(out string reason, int time, object[] param)
|
|
{
|
|
reason = String.Empty;
|
|
|
|
if (ControlModeFeedback != PressureCtrlMode.TVPressureCtrl)
|
|
{
|
|
reason = "TV is not in pressure control mode";
|
|
return false;
|
|
}
|
|
|
|
PressureSetpointByUse = (float)Convert.ToDouble(param[0]);
|
|
|
|
_rampTimer.Stop();
|
|
|
|
if (time > 0)
|
|
{
|
|
Ramp(Convert.ToDouble(param[0]), time);
|
|
}
|
|
else
|
|
{
|
|
double rate = SC.GetValue<double>($"PM.{Module}.ThrottlePressureRate");
|
|
RampByRate(Convert.ToDouble(param[0]), rate);
|
|
}
|
|
return true;
|
|
}
|
|
|
|
//public bool SetPressureToDefault(string reason, object[] param)
|
|
//{
|
|
// _rampTimer.Stop();
|
|
|
|
// if (PressureMode != PressureCtrlMode.TVPositionCtrl)
|
|
// {
|
|
// PressureMode = PressureCtrlMode.TVPositionCtrl;
|
|
// }
|
|
|
|
// PositionSetpoint = PositionDefaultValue;
|
|
// PressureSetpoint = PressureDefaultValue;
|
|
|
|
// PositionSetpointByUse = PositionDefaultValue;
|
|
// PressureSetpointByUse = PressureDefaultValue;
|
|
// return true;
|
|
//}
|
|
|
|
public bool SetPositionToZero(string reason, object[] param)
|
|
{
|
|
_rampTimer.Stop();
|
|
_rampTimer1.Stop();
|
|
|
|
if (ControlModeFeedback != PressureCtrlMode.TVPositionCtrl)
|
|
{
|
|
PressureMode = PressureCtrlMode.TVPositionCtrl;
|
|
}
|
|
|
|
PositionSetpoint = 0;
|
|
//PressureSetpoint = PressureDefaultValue;
|
|
|
|
PositionSetpointByUse = 0;
|
|
//PressureSetpointByUse = PressureDefaultValue;
|
|
|
|
return true;
|
|
}
|
|
|
|
//public bool SetPositionImmediately(string reason, object[] param)
|
|
//{
|
|
// _rampTimer.Stop();
|
|
// reason = String.Empty;
|
|
// PositionSetpoint = 0;
|
|
// return true;
|
|
//}
|
|
|
|
//private bool SetPressure(float pressure, out string reason)
|
|
//{
|
|
// PressureSetpoint = pressure;
|
|
|
|
// reason = $"{Display} pressure set to {pressure} {_unitPressure}";
|
|
|
|
// EV.PostInfoLog(Module, reason);
|
|
|
|
// return true;
|
|
//}
|
|
|
|
public bool SetTVEnable(bool isEnable, out string reason)
|
|
{
|
|
reason = String.Empty;
|
|
|
|
_rampTimer.Stop();
|
|
_rampTimer1.Stop();
|
|
//开阀时设置Ai的默认值
|
|
if (isEnable)
|
|
{
|
|
if (!_doTVValveEnable.SetValue(isEnable, out reason))
|
|
return false;
|
|
|
|
Thread.Sleep(50);
|
|
|
|
if (ControlModeFeedback != PressureCtrlMode.TVPressureCtrl)
|
|
{
|
|
PressureMode = PressureCtrlMode.TVPressureCtrl;
|
|
}
|
|
|
|
Thread.Sleep(50);
|
|
|
|
//PositionSetpoint = 0;
|
|
PressureSetpoint = PressureDefaultValue;
|
|
|
|
//PositionSetpointByUse = 0;
|
|
PressureSetpointByUse = PressureDefaultValue;
|
|
}
|
|
else
|
|
{
|
|
//PositionSetpoint = 0;
|
|
PressureSetpoint = PressureDefaultValue;
|
|
|
|
//PositionSetpointByUse = 0;
|
|
PressureSetpointByUse = PressureDefaultValue;
|
|
|
|
Thread.Sleep(50);
|
|
|
|
if (ControlModeFeedback != PressureCtrlMode.TVClose)//强关模式
|
|
{
|
|
PressureMode = PressureCtrlMode.TVClose;
|
|
}
|
|
|
|
if (!_doTVValveEnable.SetValue(isEnable, out reason))
|
|
return false;
|
|
|
|
}
|
|
|
|
reason = $"{Display} set to {isEnable}";
|
|
|
|
EV.PostInfoLog(Module, reason);
|
|
return true;
|
|
}
|
|
|
|
public bool SetTVEnableState(bool isEnable, out string reason)
|
|
{
|
|
_rampTimer.Stop();
|
|
_rampTimer1.Stop();
|
|
|
|
if (!_doTVValveEnable.SetValue(isEnable, out reason))
|
|
return false;
|
|
|
|
reason = $"{Display} set to {isEnable}";
|
|
|
|
EV.PostInfoLog(Module, reason);
|
|
return true;
|
|
}
|
|
|
|
public bool SetTVEnableRoutine(out string reason,int time,object[] param)
|
|
{
|
|
_rampTimer.Stop();
|
|
_rampTimer1.Stop();
|
|
|
|
bool isEnable = Convert.ToBoolean(param[0]);
|
|
|
|
if (!_doTVValveEnable.SetValue(isEnable, out reason))
|
|
return false;
|
|
|
|
reason = $"{Display} set to {isEnable}";
|
|
|
|
EV.PostInfoLog(Module, reason);
|
|
return true;
|
|
}
|
|
|
|
public void Terminate()
|
|
{
|
|
}
|
|
|
|
public void StopRamp()
|
|
{
|
|
Ramp(PressureSetpoint, 0);
|
|
}
|
|
|
|
public void Monitor()
|
|
{
|
|
try
|
|
{
|
|
MonitorRamping();
|
|
MonitorRampingPosition();
|
|
//MonitorClose();
|
|
}
|
|
catch (Exception ex)
|
|
{
|
|
LOG.Write(ex);
|
|
}
|
|
}
|
|
|
|
private void MonitorClose()
|
|
{
|
|
//InterLock
|
|
if (!_doTVValveEnable.Value && ControlModeFeedback != PressureCtrlMode.TVClose)
|
|
{
|
|
PressureMode = PressureCtrlMode.TVClose;
|
|
}
|
|
|
|
}
|
|
|
|
public void RampByRate(double target, double rate)
|
|
{
|
|
if (ControlModeFeedback == PressureCtrlMode.TVPressureCtrl)
|
|
{
|
|
_rampInitValue = PressureFeedback;// PressureSetpoint; //ramp 初始值取实际读取值
|
|
_rampTime = 0;
|
|
if (rate > 0)
|
|
{
|
|
_rampTime = Math.Abs((int)((target - PressureFeedback) / rate) * 1000); //根据速率计算超时时间
|
|
}
|
|
_rampTarget = target;
|
|
_rampTimer.Start(_rampTime);
|
|
}
|
|
}
|
|
|
|
private void RampByRatePosition(double target, double rate)
|
|
{
|
|
if (ControlModeFeedback == PressureCtrlMode.TVPositionCtrl)
|
|
{
|
|
_rampInitValue1 = PositionFeedback;//PositionSetpoint;
|
|
_rampTime1 = 0;
|
|
if (rate > 0)
|
|
{
|
|
_rampTime1 = Math.Abs((int)((target - PositionFeedback) / rate) * 1000);
|
|
}
|
|
_rampTarget1 = target;
|
|
_rampTimer1.Start(_rampTime1);
|
|
}
|
|
}
|
|
|
|
|
|
private void Ramp(double target, int time)
|
|
{
|
|
if (ControlModeFeedback == PressureCtrlMode.TVPositionCtrl)
|
|
{
|
|
_rampInitValue1 = PositionFeedback; //PositionSetpoint; //ramp 初始值取实际读取值
|
|
_rampTime1 = time;
|
|
_rampTarget1 = target;
|
|
_rampTimer1.Start(_rampTime1);
|
|
}
|
|
else
|
|
{
|
|
_rampInitValue = PressureFeedback;// PressureSetpoint; //ramp 初始值取当前设定值,而非实际读取值.零漂问题
|
|
_rampTime = time;
|
|
_rampTarget = target;
|
|
_rampTimer.Start(_rampTime);
|
|
}
|
|
}
|
|
|
|
private void MonitorRamping()
|
|
{
|
|
if (!_rampTimer.IsIdle())
|
|
{
|
|
if (ControlModeFeedback == PressureCtrlMode.TVPressureCtrl)
|
|
{
|
|
//压力模式
|
|
if (_rampTimer.IsTimeout() || _rampTime == 0)
|
|
{
|
|
_rampTimer.Stop();
|
|
PressureSetpoint = (float)_rampTarget;
|
|
}
|
|
else
|
|
{
|
|
PressureSetpoint = (float)(_rampInitValue + (_rampTarget - _rampInitValue) * _rampTimer.GetElapseTime() / _rampTime);
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
|
|
private void MonitorRampingPosition()
|
|
{
|
|
if (!_rampTimer1.IsIdle())
|
|
{
|
|
if (ControlModeFeedback == PressureCtrlMode.TVPositionCtrl)
|
|
{
|
|
if (_rampTimer1.IsTimeout() || _rampTime1 == 0)
|
|
{
|
|
_rampTimer1.Stop();
|
|
PositionSetpoint = (float)_rampTarget1;
|
|
}
|
|
else
|
|
{
|
|
PositionSetpoint = (float)(_rampInitValue1 + (_rampTarget1 - _rampInitValue1) * _rampTimer1.GetElapseTime() / _rampTime1);
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
|
|
public void Reset()
|
|
{
|
|
_setTvCloseTrig.RST = true;
|
|
}
|
|
}
|
|
}
|